Making Sbr Setup Display In Service Menu [Dm475] - Pitney Bowes DM300c Service Manual

Hide thumbs Also See for DM300c:
Table of Contents

Advertisement

6 • Service Menus
6.2 Making SBR
Setup Display
in Service Menu
[DM475]
1. At the main Service Menu, select Diagnostics.
Service Menu
◄ Diagnostics
◄ WOW Options
◄ Platform Options
◄ Time Functions
2. At the next screen, select SBR Diagnostics.
Diagnostics
◄ PM Diagnostics
◄ PM Maintenance
◄ Feeder/WOW Diagnostics
◄ SBR Diagnostics
3. At the next screen, select Reset SBR Status.
SBR Diagnostics
◄ Length Calibration
◄ Re-zero Thickness
◄ Last 256 Dimensions
◄ Reset SBR Status
[Back] When Done
4. At the next screen, select Reset Status.
Reset SBR Status
Remove all SBR setting.
Need Setup again for SBR.
◄ Reset Status
◄ Don't reset status
6-4
SBR Setup is only displayed if it has not been completed. If SBR Setup
does not display on the Service Menu and you need to rerun this option, fol-
low the procedure below.
5. The previous screen displays. Press
Back/C key.
SBR Diagnostics
◄ Length Calibration
◄ Re-zero Thickness
◄ Last 256 Dimensions
◄ Reset SBR Status
[Back] When Done
6. The previous screen displays.
Press Back/C key.
Diagnostics
◄ PM Diagnostics
◄ PM Maintenance
◄ Feeder/WOW Diagnostics
◄ SBR Diagnostics
7. The main Service Menu screen with SBR
Setup displays.
Service Menu
◄ SBR Setup
◄ Diagnostics
◄ WOW Options
◄ Platform Options
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)