3 • Theory Of Operation
3.10 DM475
Feeder/WOW
Theory
3-48
Throughput and Estimated Performance
The DM475 is marketed with the following throughputs for #10 or shorter
envelopes:
In non-WOW mode, there are two throughput modes for the DM 475:
Throughput Mode
Low
High
In WOW mode, the throughput will be defaulted to 80 LPM.
Sensors and Actuators
The following diagram illustrates the spacing of key sensors and rollers:
Figure 3-44 Sensors and Actuators (DM475)
LPM
Default
95
Yes
120
No
DM475
WS4
WS5
WS6
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)