4 • Troubleshooting/Diagnostics
4.3 Error Codes
Table 4-15 Image Generator Errors (22xx)
This class of errors is reported by the UIC when there are image generator errors.
Error
Description
2201
Font, graphic, barcode, or text ad component had wrong schema version
2202
Too many "indicia" components in the region map OR too many "town circle" components in the region map(s).
2203
Wrong state to do the requested operation
2204
Someone requested a change in the date duck state when there is no date field
2205
Someone requested a change in the EB duck state when there is no Entgelt Bezahlt
2206
Someone requested a change in the PIN duck state when there is no PIN field
2207
Someone requested a change in the TL/TC duck state when there is no town line field and no town circle
2208
The region maps weren't numbered consecutively OR the id of the first region map wasn't 0 (zero) OR the re-
gion map didn't contain an indicia component or a permit component or a tax graphic component or a date/time
component OR the region map had both a normal/low indicia component and a leading/lagging indicia compo-
nent OR the region map had both a normal indicia component and a low value indicia component OR the region
map had a combinations of indicia and/or permit and/or tax graphic and/or date/time components
2209
Someone tried to set the indicia type to "low" when there is no low value indicia graphic component
220A
IG_Reload was called. Now IG_LoadIndicia, IG_LoadPermit, IG_LoadTaxGraphic, IG_LoadAdInscr or IG_Load-
DateTime must be called before calling one of the "duck" functions or IG_LoadStaticVCRs or IG_LoadVari-
ableVCRs. Similarly IG_LoadReport must be called before IG_LoadNextReportPage.
220B
Region map contained an invalid component type
220C
Someone called IG_LoadIndicia or IG_LoadAdInscr when there is no indicia region map
220D
Someone called IG_LoadPermit when there is no permit region map
220E
Someone called IG_LoadTaxGraphic when there is no tax graphic region map
220F
Someone called IG_LoadIndicia when there is no indicia type selected
2210
Someone called IG_LoadPermit when there is no permit selected
2211
The blob was missing data for a set of VCRs OR the name strings was missing from the TC graphic and it's
needed
2212
The data for a graphic component was missing from the component structure given to IG_Powerup or IG_Re-
load or IG_SetIndiciaType
2213
Font used by a text ad is missing OR font used by one or more VCRs is missing OR 1D barcode font is missing
2214
A region's or VCR's starting point (column or row) and/or ending point (column or row) isn't within the print area
2215
The width and/or height of a graphic or font is zero OR the max width and/or max height of a region is zero OR
the width/height of a graphic is greater than the max width/height of the region that the graphic goes in
2216
The address of the graphic or font character is zero OR the size of the graphic or font character is zero
2217
The compressed data had a command byte with a byte count of zero
2218
When the image data is decompressed, the graphic is bigger than the given height and width
2219
The number of VCRs defined in the register groups doesn't match the number of VCR location records OR too
many VCRs have been defined
221A
A register group or text ad line or 1D barcode field has an unknown justification value.
221B
A register group has a field size that is too big OR the number of VCR definitions for a graphic doesn't match the
sum of all the register field lengths for the graphic OR the total number of VCRs for a region map is more than
the max allowed.