3 • Theory Of Operation
3.3 User
Interface
QWERTY
Keyboard
Figure 3-3 User Interface
3-2
All models are equipped with a fixed (non-user removable) Intellilink™
control center. The user interface includes a seven-line monochrome LCD
display (DM300c/DM400c) or an eight-line color LCD display (DM475), an
integrated full QWERTY keyboard, a numeric keypad, dedicated function
keys and software-defined "soft" keys.
Unlike some previous DM models, the user interface PCB does not include
any controller functions: it is a keyboard and display only. All controller func-
tions, including the PSD, are resident on the system's main logic board. See
section 3.6, PCBs, Controller (Main Logic) Board, for more information.
Tape
Meter
LED
Chute
Lock
Keys
The user interface is menu driven and offers a full range of features based
on the common DM Series system architecture. It allows the user to per-
form meter refills, store information related to indicia printing under a specif-
ic key, set postage value, and perform all user entry requirements. See the
Control Panel Unit in section 3.6 for a description of the user interface PCB.

LED States

The LED on the user interface (figure above) has three states:
Green: system is nominal (normal operating) mode.
Orange: system is in sleep mode.
Red: system fault.
The LED flashes green several times during initialization.