6 • Service Menus
6.4 Diagnostics
6-12

Feeder/WOW Diagnostics

Submenu 1
Submenu 2
Feeder/WOW
Motors
Diagnostics
Sensors
Read Encoder
Download Firmware
Reload Profiles
Print Logs
Save Logs to File
Information
[View only feeder/
WOW numeric info]
Motors
Allows you to run either the feeder motor or WOW motor at different speeds
(25%, 50%, 75%, and 100%) to verify if they are functioning. NOTE: In actual
usage, the motor frequently starts and stops (not running continuously as is
done in this test).
Sensors
Displays the current state of the sensor. Depending on the sensor, screen
may show either "Clear" or "Blocked", or "Open" or "Closed". For WOW
sensors, it includes the SBR width sensors (WS4, WS5, WS6) and thick-
ness encoder (T1).
Read Encoder
Allows you to rotate the WOW motor feed encoder one full revolution to test
its functionality.
Download Firmware
Reload Profiles
Print Logs
Save Logs to File
These items are for Engineering use only.
Submenu 3
Feeder Motor Excerciser
WOW Motor Excerciser
Feeder Sensors
WOW Sensors
Feeder Motor
WOW Motor
[Engineering Only]
[Engineering Only]
[Engineering Only]
[Engineering Only]
PCN Information
Counters
Jam Counters
DM300c/DM400c/DM475 Service Manual (SV61801 Rev. D)
Submenu 4
[Run at different speeds]
[Run at different speeds]
["Clear" or "Blocked"
"Open" or "Closed"]
[Includes SBR sensors
and encoder]
[Encoder Status]
[Encoder Status]
XPT Entry
Length Error
WOW Timeout
Reset Counters