NEC Electra Elite IPK II System User Manual page 1107

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
System Availability
Terminals
ITH-4D/8D/16D-2/3 TEL
IP Adapter
Required Component(s)
PVA(X)-U( ) ETU
Programming
Programming – VoIP MG16 ETU
These programs are always required with the VoIP MG16 feature.
Programming – Static IP Address
In addition to the system programming for the MG 16 ETU, the IP telephone also has options which must
be programmed from the telephone itself. Be sure to set both the system and telephone options.
10-12-01
through
10-12-03
CPUII Network Setup
84-05-01
VoIP IP Address – IP Address
For each ETU, enter the IP address for the MG 16 ETU (default: slot 1 = 172.16.0.20, slot 2 =
172.16.0.21, etc.). The IP address should be increased according to the number of VoIP MG16
ETUs.
84-05-02
VoIP IP Address – LAN Interface
For each MG16 ETU, enter the Mode/speed setting (default: Auto).
84-05-03
VoIP IP Address – Master/Slave
For each MG16 ETU, enter the MASTER/Slave setting.
There can be one MG16 only assigned as MASTER and additional MG16 ETUs must be set as SLAVE.
84-05-04
VoIP IP Address – Subnet Mask
For each ETU, enter the Subnet Mask used by the MG16 (default: 255.255.0.0).
84-05-05
VoIP IP Address – Default Gateway
For each ETU, enter the default Gateway used by the MG16 (default: 0.0.0.0).