Chapter 4
MtcCEX: Unable to generate SYSERR packet. Status = 0xy
Variables
y – an error status displayed in hexadecimal
Severity
Error
Description
This message displays in a Windows NT blue screen on a monitor attached directly to a CE
when the HP NetServer AA CE Transport experiences an unexpected failure while preparing
to generate a system error. This error is fatal to CE operations and is followed by a reset of the
CE.
Hardware/Software
This message most likely indicates a hardware failure in the CE that displays the message.
Action
The CE will be reset and will be resynchronized into the system unless the number of failures
exceeds a threshold. If the threshold is exceeded, the CE is marked faulted and is not
resynchronized. In this case, the CE is diagnosed offline.
After you repair or replace the CE, manually return it to service.
MtcCEX: Unable to initialize QI mechanism. Status = 0xy
Variables
y – an error status displayed in hexadecimal
Severity
Error
Description
This message displays in a Windows NT blue screen on a monitor attached directly to a CE
during CE operating system boot when the HP NetServer AA CE Transport experiences an
unexpected failure while attempting to perform MtcCEX driver initialization. This error is
fatal to CE operations and is followed by a reset of the CE.
Hardware/Software
This message indicates a software failure while attempting to map the P6 APIC.
Action
The CE is reset, and a reboot may be attempted. If this failure recurs repeatedly, the CE will
be marked faulted.
• If this failure recurs, verify that the CE's system memory meets the HP NetServer AA size
• If the problem persists, contact your service provider for assistance.