HP NetServer AA 4000 Manual page 220

Hp netserver aa 6200 solution release 3.0 messages
Hide thumbs Also See for NetServer AA 4000:
Table of Contents

Advertisement

Chapter 13
IOPn.MtcMon FRU: The MIC on Compute Element CEx has detected a misconnected cable on its IOPy port, or the
CEx MIC has had its ID set incorrectly.
Variables
x – the ID of the CE that detected the misconnection or has its MIC ID set incorrectly
y – the ID of the CE to IOP port that is in error
Severity
Error
Description
This condition occurs when the MIC on a booting or synchronizing CE determines that it is not
cabled correctly based on its assigned ID. This indicates either a problem with the assigned ID
or a physical cabling problem.
Action
• Using the Marathon MIC setup during POST, ensure that the ID of the CEy MIC is set
• Examine the cabling between the CE and the IOPs to ensure that the connections are
• If this problem persists, contact your service provider for assistance.
IOPn.MtcMon FRU: The MIC on I/O Processor IOPx has detected a misconnected cable on its CEy port, or the CEy
MIC has had its ID set incorrectly.
Variables
x– the ID of the IOP that detected the misconnection
y – the ID of the IOP to CE port that is in error, or the CE that has its MIC ID set incorrectly
Severity
Error
Description
This condition occurs when the MIC on a booting or joining IOP determines that it is not
cabled correctly based on its assigned ID. This indicates either a problem with the assignment
or a physical cabling problem.
Action
• Using the Marathon MIC setup during POST, ensure that the ID of the CEy MIC is set
• Examine the cabling between the IOP and CEs to ensure that the connections are correct.
• If this problem persists, contact your service provider for assistance.
210
correctly.
correct.
correctly.
MtcMon Messages

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netserver aa 6200

Table of Contents