IOPn.MtcScsiP status: DISKn did not come ready, and it will be marked offline.
Variables
n – the disk number; for example, DISK0, DISK1, DISK2
Severity
Error
Description
The reported disk was found, but it did not come ready for use.
Action
• Make sure the disk is turned on.
• If the disk is powered on, reboot the IOP that contains the disk, and break into the SCSI
• Use the program to set "Send Start Unit Command" for the disk. Do not set this option for
• If all else fails, power cycle the IOP to attempt to clear the condition.
• If the condition persists, it may be time to replace the disk, or contact your service
IOPn.MtcScsiP status: DISKn did not power up properly, and it will be marked offline.
Variables
n – the disk number; for example, DISK0, DISK1, DISK2
Severity
Error
Description
A disk did not appear to power up properly. This may occur for a variety of reasons. For
example; it may be powered off, it may not be plugged into the SCSI bus, it may have failed,
there may be a problem with SCSI termination on the bus, or it may be misconfigured.
Action
• Reboot the IOP, and verify the disk is powered on, plugged into the SCSI bus, and has
• If the condition persists, contact your service provider for assistance.