Chapter 13
IOPn.MtcMon FRU: IOPx/CEy tuple power supply failure.
Variables
x – the ID of the IOP whose tuple has lost power
y – the ID of the CE whose tuple has lost power
Severity
Error
Description
All components in the tuple have lost power.
Action
• Check the power supply connections to the tuple components.
• Make sure that the line voltage being supplied to the tuple components is within
IOPn.MtcMon FRU: IOPx <-> CEx tuple processing capability failure.
Variables
x – the ID of the tuple containing the IOP and CE with the fatal condition
Severity
Error
Description
This message is generated when both the CE and IOP in a tuple report a fatal condition.
Usually, this is the result of:
• A serious communication problem between the components
• A secondary fault that occurred in one unit while another one was being handled in the
This message encompasses all failures of both the IOP and CE within a single tuple except for
power failure.
Related Messages
IOPn.MtcMon FRU: IOPx tuple power supply failure.
Action
• Run the MIC Connectivity Test in the MIC BIOS utility between the IOPs and the CEs to
• If the condition persists without indicating any other failed components, contact your
operational parameters.
other unit
ensure that the MIC adapters and the connection between them are functioning correctly.
service provide for assistance.
MtcMon Messages