Advertisement

Chapter 14
IOPn.MtcScsiP status: DEVICEn location does not contain the expected device type.
Variables
n – the device number; for example, DISKn, CDROMn, TAPEn
Error
Description
A device located at a configured SCSI address was not the expected device type. For example,
the software may have been configured to expect a disk drive at a particular SCSI address, but
instead, it encountered a CDROM drive.
Action
• Verify the HP NetServer AA configuration file is set up properly.
• If so, check whether the installation of any new SCSI hardware devices or adapters may
IOPn.MtcScsiP status: DEVICEn powered up successfully.
Variables
n – the device number; for example, DISKn, CDROMn, TAPEn
Informational
Description
A configured device has been found and appears to have powered up without problems.
Action
No action is required.
IOPn.MtcScsiP status: DEVICEn was not found, and it will be marked offline.
Variables
n– the device number; for example, DISKn, CDROMn, TAPEn
Severity
Error
Description
No device at a configured SCSI address was found. This may be because the device is powered
off, not present, not connected to the SCSI bus, has failed, or is misconfigured, for example.
Action
• Verify the HP NetServer AA configuration file is set up properly.
• If so, power off the IOP and verify the device is powered on, connected to the SCSI bus,
IOPn.MtcScsiP status: Disk could not be enabled.
Severity
Error
Description
The administrator was unable to enable the specified disk using the HP NetServer AA
Manager.
Action
No action is required.
have caused a change in the physical SCSI address of a device.
and has not failed.
MtcScsiP and MtcScsiR Messages
313