Chapter 2
Negotiating HP NetServer AA startup with IOPx. . .
Variables
x – the ID of the IOP with which communication has been established and the startup process
is beginning
Severity
Informational
Description
Communication has been established with the specified IOP, and the startup process is
beginning.
Action
No action is required.
No MIC identity found: A MIC identity must be assigned and saved. Press <Enter> to continue.
Severity
Informational
Description
The MIC element identity (CE1, CE2, IOP1, IOP2) has not been specified in non-volatile
memory (or has been reset to the "Unknown" setting).
Action
• Select the appropriate element identity.
• Save the setting in non-volatile memory.
• Upon exiting the setup utility, reboot the appropriate element to reinitialize the firmware
Performing client tests. Please ensure remote port(s) are in server mode.
Severity
Informational
Description
For a client test, the ports to be included in the test must be physically connected and listening
in server mode.
Action
When the remote port(s) are in server mode, press any key to continue the test.
Performing external loopback tests. Please ensure MIC ports are connected.
Severity
Informational
Description
For an external loopback test, the MIC ports must be connected with a fiber cable.
Action
When the ports are connected, press any key to continue the test.
to the new setting.