HP NetServer AA 4000 Manual page 247

Hp netserver aa 6200 solution release 3.0 messages
Hide thumbs Also See for NetServer AA 4000:
Table of Contents

Advertisement

Chapter 13
IOPn.MtcMon status: CEx cannot be removed because it is already offline.
Variables
x – the ID of the CE that is offline
Severity
Warning
Description
This message is generated if you issue a CE Remove command and the CE is already offline.
Hardware/Software
This message is generated as a result of a software condition.
Action
• No action is required. The message indicates that no action was necessary in response to
IOPn.MtcMon status: CEx cannot be synchronized because IOPy cannot communicate with it.
Variables
x – the ID of the CE that cannot be synchronized
y – the ID of the IOP that cannot communicate with the CE
Severity
Error
Description
The specified CE cannot be synchronized into the system configuration because the specified
IOP is active, and the CE is not in communication with it.
Hardware/Software
This message is generated in response to the failure of an Endurance System Interconnect,
usually due to a hardware malfunction.
Action
• Examine the Endurance Manager on the specified IOP to verify that the IOP is not in
• Examine the physical Interconnect to determine if it is properly connected, and repair it if
• In some cases, powering the CE off and then back on can resolve the problem.
• If the condition continues, or if the cause of this message cannot be determined, contact
the command.
communication with the CE.
it is not.
your service provider for assistance.
MtcMon Messages
237

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netserver aa 6200

Table of Contents