MIC cable fault on portn: reason.
Variables
n – the ID of the port with the cable fault; either 1 or 2
Severity
Error
Description
This message indicates that a hardware cable fault was detected on the specified port. The
possible reasons for the cable fault are:
• Reset – the element at the other end of the port was reset or lost power.
• Cable Gone – the cable was removed from the specified port or from the element at the
Action
• To verify that the hardware and cabling are functioning properly, run the MIC BIOS
• If the error persists, contact your service provider for assistance.
MIC communication lost with IOPx
Variables
x – the ID of the IOP with which the MIC has lost communication
Severity
Error
Description
The MIC BIOS lost communication with the specific IOP and terminated the boot or
synchronization process. Often there is another error displayed prior to this with additional
detail about the cause. There may also be related events in the startup IOP's event log.
Action
No action is required.
MIC error status status: module line line
Severity
Error
Description
The MIC BIOS received an error status while communicating with the MIC adapter. This is
probably due to a hardware fault.
Action
• Run the MIC BIOS client-server diagnostics between the CE and the IOP providing
• If the error persists, write down the status code, module, and line number indicated, and
52
other end of the port connection, or the cable was severed.
client - server diagnostics between the local system and the specified port.
startup services to verify that the hardware is functioning properly.
contact your service provider for assistance.