IOPn.MtcMon FRU: IOPx MIC fault.
Variables
x – the ID of the IOP whose MIC is malfunctioning and not receiving or transmitting messages
Severity
Error
Description
The MIC adapter on the specified IOP is both malfunctioning and also not receiving or
transmitting messages properly. This is probably due to a hardware problem with the specified
MIC.
Action
• Run the MIC Connectivity Test in the MIC BIOS utility to validate that the paths between
• Consider replacing the IOP MIC if this condition persists.
IOPn.MtcMon FRU: IOPx Power supply failure.
Variables
x – the ID of the IOP whose power supply was interrupted
Severity
Error
Description
The power supply to the specified IOP was interrupted.
Action
• Make sure that the IOP has not been powered off.
• Check the power supply connections to the specified IOP.
• Check the internal power supply function of the IOP.
• Make sure that line voltage to the IOP is within operational parameters.
• Replace the IOP MIC.
IOPn.MtcMon FRU: IOPx processing capability failure.
Variables
x – the ID of the IOP whose processing capability has failed
Severity
Error
Description
The ability of the specified IOP to function as part of the Endurance server was compromised
due to:
• A system crash or stop error with screen dump
• An inconsistency detected in Endurance server software
• A malfunction of the IOP or CE that was not qualified by a transport (MIC) level error,
• Excessive disk or CPU load
Action
Use diagnostics to determine if the specified component is functioning properly.
204
the component and the Endurance server are functioning properly.
cable gone indication, or power gone indication