Chapter 13
IOPn.MtcMon status: The CE operating system shutdown request completed successfully.
Severity
Informational
Description
This message is generated after successfully completing a CE_O/S Shutdown Operation
command.
Related Messages
IOPn.MtcMon status: CE operating system shutdown has been requested by
the operator.
IOPn.MtcMon status: The Windows NT operating system on the CE(s) is being
shut down.
IOPn.MtcMon status: The Windows NT operating system on the active CE(s)
has been shut down by operator request.
IOPn.MtcMon status: CEx has been removed from service.
Hardware/Software
This message is generated as a result of the successful completion of a software process.
Action
• Unless this error occurs frequently, you can ignore it.
• Otherwise, view the message data as Words. The last longword (8 bytes) of data should
IOPn.MtcMon status: The CE1 and CE2 PCI configurations do not match.
Severity
Error
Description
The PCI configurations of the two CEs do not match. CE synchronization cannot be performed
until this condition is resolved.
Hardware/Software
This message is generated as a result of a CE hardware configuration error.
Action
• Shut down one or both CEs.
• Reconfigure the hardware so the PCI configurations are identical. You may need to use the
• Power up the CEs and allow them to synchronize.
284
contain a Windows NT error code that can be used by your service provider to help
diagnose the problem.
system BIOS setup to reset the PCI configuration, disable devices that are unsupported on
the CEs, or assign identical resources to the MICs on both CEs.
MtcMon Messages