IOPn.MtcScsiP status: Command to DISKn not valid because it is a non-mirrored disk. HP NetServer AA Manager
request to non-mirrored disk was ignored.
Variables
n – the disk number; for example, DISK0, DISK1, DISK2
Severity
Error
Description
The administrator used HP NetServer AA Manager to issue a disk operation command to a
non-mirrored disk. The operation is not allowed on a non-mirrored disk, and it has been
rejected.
Action
No action is required.
IOPn.MtcScsiP status: Configured ADAPTERn failed to reset bus BUSx. Disks connected to this adapter may be
marked faulted.
Variables
n – the adapter number; for example, ADAPTER0, ADAPTER1, ADAPTER2
x – the bus number; for example, BUS0, BUS1, BUS2
Severity
Informational
Description
HP NetServer AA SCSI software requested the specified SCSI adapter to reset its SCSI bus.
However, the reset request did not succeed. Any disks connected to this adapter may fail read
or write requests, causing the disks to be marked as faulted. However, it is unlikely that any
particular disk may actually have failed.
Action
Make sure SCSI termination and cabling is correct. If a problem persists, contact your service
provider for assistance.
IOPn.MtcScsiP status: Configured ADAPTERx has a misconfigured bus ID BUSn. Use the HP NetServer AA
Configuration Utility to change the bus ID.
Variables
x – the adapter number; for example, ADAPTER0, ADAPTER1, ADAPTER2
n – the bus number; for example, BUS0, BUS1, BUS2
Severity
Error
Description
The HP NetServer AA Configuration Utility was used to configure a SCSI bus ID for an
adapter, but the adapter has no such bus ID.
Action
Use the HP NetServer AA Configuration Utility to change the bus ID to a valid value.