Chapter 13
IOPn.MtcMon status: IOPx was removed from service to allow the CE operating system to be booted.
Variables
x – the ID of the IOP that was removed
Severity
Error
Description
The specified IOP was removed from the Endurance server configuration to allow the CE
operating system to boot. This action is taken because the IOP that was removed could not
communicate with any of the available CEs; as a result, it was preventing the CE operating
system from being booted.
Related Messages
IOPn.MtcMon status: IOPx has been removed from service.
IOPn.MtcMon status: The boot process has started for CEx.
Hardware/Software
This message is typically generated as a result of a hardware error on a CE-to-IOP
Interconnect.
Action
• Examine the Interconnect between the specified IOP and the CEs.
• Manually repair the Interconnect and allow the IOP to rejoin the configuration.
IOPn.MtcMon status: Monitor initialization failed on the local IOP.
Severity
Error
Description
The Monitor could not initialize. The IOP is not activated.
Hardware/Software
This message occurs as a result of a software problem.
Action
• This message is generated as a result of a problem with the Endurance software
• This message might also be generated if a Monitor subcomponent detects a resource error
• If the condition persists, disable the IOP to allow the Endurance server to operate, and
266
configuration and indicates that the Endurance software is not properly installed. This
usually occurs because the Windows NT Registry information for the Endurance software
is corrupt.
that prevents it from successfully initializing. The Endurance software should be
reinstalled on the IOP.
contact your service provider for assistance.