Restore Other Configuration Changes
The library does not automatically save a backup when you make changes
to any of the library configuration settings other than those for partitions.
If you made configuration changes after the creation date of the auto save
file you used, you will need to use the options in the Configuration menu
to repeat those changes after the restore is complete. This includes entering
your option keys.
Use the partition wizard to update the library inventory to reflect the
correct number of slots assigned to the partition.
1. Log in as a user with superuser or administrator privileges.
2. From the toolbar menu, select Configuration > Partitions. The
3. Select Edit for the partition to which the unassigned slots should
4. Select Next to advance through the partition configuration screens until
5. Decrease the number of storage slots assigned to the partition.
6. Select Next to advance through the remainder of the screens without
7. Select Next. The summary screen re-displays; select Save.
8. Repeat Step 2 through Step 6, this time increasing the number of
9. Review the information on the Summary screen and confirm that all
December 2008
Partitions screen displays.
belong.
you reach the Chambers and Drives screen.
Figure 163 The Chambers and Drives screen.
making any additional changes until you reach the Save Library
Configuration screen.
storage slots by the same number.
settings are correct for this partition's configuration.
If the configuration information is correct, proceed to Step 10.
If the configuration information is not correct, either:
Select Cancel to configure the partition again from the beginning.
Restore the Library Configuration