Electrical system
•
Loosen the lock nut of the set screw.
•
Act on the adjuster screw, screwing it
in to decrease the tensioning frequen-
cy or unscrewing it to increase it.
•
Tighten the fixing screws (1) and (2) of
the alternator to the specified torque.
WARNING
It is essential to tighten the fixing screws to measure the
tensioning frequency correctly.
Locking torques (N*m)
Fixing screw (1)
45 - 50 Nm (33.19 - 36.88 lb ft)
screw (2)
20 - 24 Nm (14.75 - 17.70 lb ft)
•
Measure the tensioning frequency of
the alternator belt again.
Characteristic
Alternator belt frequency
180 Hz