Cooling system
•
Fill the expansion tank with the speci-
fied anti-freeze liquid up to the MAX
mark.
•
Fit the expansion tank cap.
•
Start the engine and let it idle until the
radiator fan starts.
NOTE
THE COOLING SYSTEM OF V100 IS SELF-BLEEDING.
ONCE THE RADIATOR AND EXPANSION TANK ARE FIL-
LED CORRECTLY AND THE ENGINE IS RUNNING UNTIL
THE RADIATOR FAN COMES STARTS, NO FURTHER AC-
TION IS REQUIRED TO PURGE THE CIRCUIT.
Characteristic
Radiator cooling fan start-up
101° C
Radiator cooling fan shut-off
98° C
•
Switch off the engine and top up the coolant level in the expansion tank.
Removing the radiator
PERFORM THE INDICATED OPERATIONS WHEN THE ENGINE IS COLD.
•
First remove the side fairings.
•
Remove the screw fixing the horn.
COOL SYS - 334