Cooling system
•
Remove the pipe from the "indicator
light" fitting on the water pump.
•
Remove the bleed screw and allow the
coolant to drain completely from the
water pump.
Cooling circuit filling
•
Insert the bleed screw on the water
pump using a NEW sealing washer
and tighten it to the specified torque.
•
Refit the pipe on the "indicator light" fit-
ting of the water pump.
COOL SYS - 332