Unscrew the lower calmp located inside the heat
shield.
Remove the heat shield from the exhaust manifold
by loosening the metal calmps.
When reassembling, loosen the calmps and place
the heat shield on the manifold.
Tighten the upper and lower clamps and the fixing
screw to the prescribed torque.
WARNING
DURING REASSEMBLY, USE NEW METAL CLAMPS.
Remove the exhaust end first.
Disconnect the lambda probe connec-
tor (1) on both sides.