V100 E5
LH HEAD
To adjust the valves of the LH head, follow the
procedures for the RH head but with the difference
of:
Turn the engine COUNTER-CLOCK-
WISE and bring the LH piston to Top
Dead Centre.
NOTE
THE HOLE ON THE PINION MARKED "PMS SX" MUST BE
ALIGNED WITH THE HOLE ON THE CRANKCASE.
Make sure that the lobes of the cam-
shafts are facing up and convergent.
Cooling system
Level check
Shut off the engine and wait until it
cools off.
Keep the vehicle upright with both
wheels on a flat surface.
Looking from right side of the vehicle,
behind the steering headstock, make
sure that the fluid level in the expansion
tank is between the "MIN" (minimum)
and "MAX" (maximum) marks.
WARNING
CARRY OUT THE CHECK AND TOP UP THE REFRIGER-
ANT LIQUID WITH THE ENGINE SWITCHED OFF AND
COLD.
Maintenance
MAIN - 81