V100 E5
Neutral sensor
GEAR SENSOR
Function
It is used to indicate to the ECU which gear is en-
gaged.
Operation / Operating principle
Each gear engaged has a sensor position, which
in turn will have a higher output voltage as the gear
engaged increases.
Position:
•
On the cover of the box of the gearbox,
under the selector shaft.
Output voltage:
•
First gear: 0.625 V ± 0.1 V
•
Second gear: 1.375 V ± 0.1 V
•
Third gear: 2.125 V ± 0.1 V
•
Fourth gear: 2,875 ± 0.1 V
•
Fifth gear: 3.625 V ± 0.1 V
•
Sixth gear: 4.375 V ± 0.1 V
•
NEUTRAL: 1 V ± 0.09 V
Key
(1) Gear sensor
1. Gear signal.
2. Neutral signal.
3. Earth.
4. Power supply.
(2) 11MP ECU
Electrical system
ELE SYS - 145