V100 E5
•
Once the brake calliper pipes are connected, remove the protective caps from the inlet ports
from the brake pumps and connect the respective pipes to the ABS modulator
•
Remove the plugs of the brake pump tanks and fill them with new brake fluid
CAUTION
PERFORM THE STANDARD BRAKING SYSTEM BLEEDING PROCEDURE, AS DESCRIBED AT
THE END OF THE CHAPTER.
•
Fill the reservoirs and refit the caps
•
Check the stroke and sensitivity of the front brake lever and the rear brake pedal
•
If the brake pedal or lever stroke is too long after carrying out the bleeding procedure, check
the braking system for leaks and, if none are found, bleed the system using the diagnostic
tool, as described.
•
Disconnect the flexible bleeder pipes and re-tighten the bleeder screws, applying the correct
torque
ABS CONTROL UNIT CONNECTOR INSERTION PROCEDURE
•
Check the initial position of the connection clip lever.
•
When the connector is fully inserted,
the distance between the connector
and the ABS control unit must be 7.5
mm (0.29 in).
Braking system
BRAK SYS - 287