MOTO GUZZI V100 E5 2023 Service Station Manual page 287

Table of Contents

Advertisement

V100 E5
Once the brake calliper pipes are connected, remove the protective caps from the inlet ports
from the brake pumps and connect the respective pipes to the ABS modulator
Remove the plugs of the brake pump tanks and fill them with new brake fluid
CAUTION
PERFORM THE STANDARD BRAKING SYSTEM BLEEDING PROCEDURE, AS DESCRIBED AT
THE END OF THE CHAPTER.
Fill the reservoirs and refit the caps
Check the stroke and sensitivity of the front brake lever and the rear brake pedal
If the brake pedal or lever stroke is too long after carrying out the bleeding procedure, check
the braking system for leaks and, if none are found, bleed the system using the diagnostic
tool, as described.
Disconnect the flexible bleeder pipes and re-tighten the bleeder screws, applying the correct
torque
ABS CONTROL UNIT CONNECTOR INSERTION PROCEDURE
Check the initial position of the connection clip lever.
When the connector is fully inserted,
the distance between the connector
and the ABS control unit must be 7.5
mm (0.29 in).