MOTO GUZZI V100 E5 2023 Service Station Manual page 112

Table of Contents

Advertisement

Electrical system
Position the ammeter clamp (1) on the
cable of the fuse (3).
With the ignition switch in the ON po-
sition, but with the engine stopped,
there will be a continuous current draw
of 3.372A.
NOTE
Perform the measurements shown below with the lights
off.
The readings may vary from those shown depending on
the ambient temperature and the temperature of the in-
stallation itself; therefore, similar values, although not ex-
actly the same, are still significant to certify the correct
operation of the charging system.
With the engine at idle speed the cur-
rent delivered (1) is 15.53 A and the
voltage on the battery (2) is 14.14 V.
With the engine at 3,500 rpm the cur-
rent delivered (1) is 20.07 A and the
voltage on the battery (2) is 14.13 V.
With the engine at 5500 rpm the cur-
rent delivered (1) is 20.25 A and the
voltage on the battery (2) is 14.16 V.
NOTE
When the voltage at the load reaches 14.82V, the generator
output current will be close to zero.