Cable and fiber installation
............................................................................................................................................................................................................................................................

10/100BaseT backplane ethernet cable installation

Description
This section describes how to connect the 10/100BaseT cables to the Alcatel-Lucent 1665
DMX high-capacity shelf backplane and route the cables out of the bay and to the
10/100BaseT terminating equipment (for example, a 110/RJ45
Perform this procedure if 10/100BaseT cables are required.
The next section covers installation of Ethernet cables connected directly to SFP modules
on circuit pack faceplates if applicable.
Steps
........................................................................................................................................................................................................................
1
See the engineering job specification. Obtain the 100BASE-TX Ethernet cables per
Table 3-12, "10/100BaseT ethernet cable assemblies" (p. 3-34)
group where each cable will be used. Label the cables, indicating bay, shelf and function
group (A, B, C or D) at each end.
........................................................................................................................................................................................................................
2
Connect the function group cables at the Alcatel-Lucent 1665 DMX high-capacity shelf
end, carefully matching the correct connector with the appropriate backplane connectors
as shown in
"10/100BaseT ethernet connections" (p.
Note:
maximum of 6.5 in-lb. Do not overtighten.
............................................................................................................................................................................................................................................................
3 - 3 2
Figure 3-8, "10/100BaseT cable installation" (p.
100BASE-TX Ethernet cable retaining screws must be tightened to a
10/100BaseT backplane ethernet cable installation
3-33). See
3-35).
®
punch-down block).
and note the function
Table 3-13,
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010