Operational tests
........................................................................................................................................................................
................................................................................................................................................
4
To verify that all cross-connections are deleted, select View> Cross-Connections.
................................................................................................................................................
5
Choose shelf (Alcatel-Lucent 1665 DMX) and click select.
................................................................................................................................................
6
Verify that no alarm LEDs are lit and no FAULT LED is lit on any circuit pack.
If any alarm is present, see Alcatel-Lucent 1665 Data Multiplexer (DMX) Alarm
Messages and Trouble Clearing Guide, 365-372-302.
................................................................................................................................................
7
If desired, reconnect the office alarm cable at this time.
................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
........................................................................................................................................................................
7 - 2 0
S
F
T E P S
Table I-3, Installation acceptance
Final operations
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2