Operational tests
........................................................................................................................................................................
................................................................................................................................................
3
Click Select.
................................................................................................................................................
4
Note the Active Path.
The M1 OLIU is associated with Ring 1 and the M2 OLIU is associated with Ring 2.
................................................................................................................................................
5
In the Switch Type: pull-down, choose Manual.
................................................................................................................................................
6
Click Apply, then Yes.
Requirement: The ring that was active in
is now active.
................................................................................................................................................
7
In the Switch Type pull-down, choose Clear.
................................................................................................................................................
8
Click Apply, then Yes.
................................................................................................................................................
9
Repeat
................................................................................................................................................
10
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

External timing verification

Description
This test should be performed if the Alcatel-Lucent 1665 DMX shelf is going to be
externally timed. The shelf timing cable must be installed and connected between the
Alcatel-Lucent 1665 DMX shelf and the office timing source (BITS clock) and the timing
source must be active.
........................................................................................................................................................................
7 - 1 0
Step 4
through
Step 8
S
F
T E P S
Step 4
to verify a switch back to the original ring.
Table I-3, Installation acceptance
External timing verification
is no longer active and the other ring
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010