Alcatel-Lucent 1665 Installation Manual page 195

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Software download and circuit pack installation
............................................................................................................................................................................................................................................................
Result:
OLIU circuit pack. The FAULT, MJ and NE LEDs will light on the SYSCTL due to
DCC alarms created by optically looping the OLIUs. These SYSCTL LEDs will
remain lit until the DCC is disabled. See
equipment and cross-connect tests (p. 6-6)
........................................................................................................................................................................................................................
6
Starting with slot A1, fully seat the circuit pack slotted there using a steady pressure on
both of the faceplate latches at the same time until the circuit pack is fully seated.
Note:
cables attached in the back of the shelf.
The ACTIVE and FAULT LEDs should light when circuit packs are inserted and the
FAULT LED should extinguish after a short period of time. Some circuit packs such as
may take several minutes before their FAULT LEDs extinguish.
........................................................................................................................................................................................................................
7
Continue seating the circuit packs with slot A2 and then on to B1, B2, G1, G2, C1, C2,
D1, and D2.
........................................................................................................................................................................................................................
8
Fully seat Blank packs in any other unfilled slots.
Blank Types
LNW177D w/o PEMS
LNW98 w/o PEMS
LNW177D w/ PEMS
If installing the Fiber
Bracket Kit
LNW98 w/ PEMS
If installing the Fiber
Bracket Kit
LNW177D w/ Fiber Bracket
Installed
LNW98 w/ Fiber Bracket
Installed
Notes:
* The fiber bracket kit is used in conjunction with the LNW177D and LNW98 that
is equipped with the PEMS.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
After a few minutes the flashing FAULT LEDs should extinguish on each
All electrical circuit packs must be slotted in the function slots with the proper
Comcode
108950585
109412866
108950585
848949871
*
109412866
848949871
*
848960175
848960167
Chapter 6, "Installation
to clear the alarms.
Series
Continue with
S1:2
Step 10
S1:2
Step 10
S1:3
Step 10
NA
Step 9
S1:3
Step 10
NA
Step 9
S1:3
Step 10
S1:3
Step 10
Circuit pack installation
tests",
Local
5 - 5

Advertisement

Table of Contents
loading

Table of Contents