Table Ds3 Cable Assemblies With Bnc With 12-Ds3 (Lnw16/Lnw18) - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Cable and fiber installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
Table 3-9 Table DS3 Cable assemblies with BNC with 12-DS3 (LNW16/LNW18)
Description
12 individual 735A coaxial cables
with 12 ITT Canon 75-ohm BNC
plugs shipped loose.
DS3#1-12 Cables with no BNC,
LNW16, LNW18 only
849040779 uses 735A cable, and
450 ft is the maximum amount of
735A allowed between two
Alcatel-Lucent 1665 DMXs
849041710 and lengths > 450 ft
use ~10ft 735A spliced to 734D
cable and 900 ft is the maximum
amount of 734D allowed between
two Alcatel-Lucent 1665 DMXs.
This splice is factory made.
Stagger the splices in the cable
rack to save space
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
S
F
T E P S
Cable
assembly #
848955407
848955415
848955423
848955431
848548277
848980504
848548285
848548293
848548301
848548319
848815742
848815734
848815759
12-DS3/EC1 and TMUX (LNW16 LNW18) cable installation
Table I-3, Installation acceptance
Alcatel-Lucent 1665 DMX
backplane connections
Cable length
(feet)
Output
10
20
J1 DS3 1-12
30
40
J3 DS3 1-12
50
60
J6 DS3 1-12
100
150
J8 DS3 1-12
250
450 (NE to NE)
450 (NE to NE)
750 (NE to NE)
900 (NE to NE)
checklist.
Input
Function Group A
J2 DS3 1-12
Function Group B
J4 DS3 1-12
Function Group C
J5 DS3 1-12
Function Group D
J7 DS3 1-12
3 - 2 9