Physical installation and powering
I
............................................................................................................................................................................................................................................................
Table I-1
Quantity
1
1
1
1
1
1
1
1
1
1
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
Tool, test equipment and accessories required
Description
Screwdriver(s)
Tube NO OX
ITE R-326
6
*
Thomas & Betts
R-
5648B Crimping Tool
Paladin
Coaxial Wire
Stripper R-5648B
Replacement Paladin
Cassette R-5648B D5
Wire-Wrap Gun
R-4496A
Impact Tool -Wire
R-5974
ESD Wrist Strap
R-4987C
Torque Wrench
R-5952
Multimeter (Optional)
ITE-6379C
Ohmmeter
ITE-6379C
DS1 Error Rate Test Set
ITE-7113
Comments
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit
breakers to the OFF position.
The crimping tool and wire stripper are only
required if installing DS3 cables. The replacement
cassette is for the wire stripper tool.
The wire-wrap gun is required for terminating
DS1 cable and must be able to accommodate 24
gauge wire.
The impact tool is required for terminating
Ethernet cable onto a 110 type panel.
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
A torque wrench (50-250 IN-LBS) is used when
Alcatel-Lucent 1665 DMX
tightening the
to the frame. It is also used when reattaching the
mounting brackets to the Alcatel-Lucent 1665
DMX shelf.
The voltmeter must be capable of measuring DC
voltage in the 40 to 60 volt range. The use of the
voltmeter is optional since the shelf will alarm or
shut down if the proper voltage is not supplied.
An ohmmeter is required to verify that the
Alcatel-Lucent 1665 DMX
grounded.
A DS1 error rate test set is required for testing of
DS1 cabling. A T-BERD 2209 or equivalent is
recommended.
Overview
shelf
is properly
I- 3