Clearing Alarms - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
3
Select the desired DS3 port by clicking the + sign next to the CP.
........................................................................................................................................................................................................................
4
Highlight the port and click Select.
........................................................................................................................................................................................................................
5
Next to Line Build Out: choose the LBO value determined in
........................................................................................................................................................................................................................
6
Repeat
with DS3 or TMUX circuit packs.
........................................................................................................................................................................................................................
7
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

Clearing alarms

Description
In order to clear standing alarms the Alcatel-Lucent 1665 DMX synchronization will be
optioned for "Free Running." The DCC will be disabled in order to prevent DCC alarms
from being generated due to the optical loopback on the main OLIUs.
........................................................................................................................................................................................................................
1
Select Configuration > Timing/Sync...
Result:
........................................................................................................................................................................................................................
2
OK
Click
........................................................................................................................................................................................................................
3
Select Configuration > DCC Terminations...
........................................................................................................................................................................................................................
4
From the Port AID: pull-down, select dcc-m1-1.
............................................................................................................................................................................................................................................................
6 - 4
Step 1
through
Step 5
S
F
T E P S
From the Timing Mode: pull-down, choose Free Running.
.
for all DS3 ports in all function unit slots that are populated
Table I-3, Installation acceptance
Clearing alarms
Step
1.
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010