Oc-48 (Low-Speed) Testing - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
19
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

OC-48 (low-speed) testing

OC-48 low-speed testing procedure
Perform the following steps for all Alcatel-Lucent 1665 DMX shelf Function unit or
Growth slots containing OC-48 (LNW31 or LNW402) OLIU.
Note:
on the OLIU, make the connections at the LGX equipment in order to verify correct
installation and labeling of the fibers.
LBOs are installed on the OLIU faceplate IN port.
........................................................................................................................................................................................................................
1
Identify the function groups that contain an OC-48 OLIU circuit pack and fully insert the
OLIU into the shelf.
Requirement:
OLIU.
........................................................................................................................................................................................................................
2
Insert a 15-dB LC-type LBO into the IN connector of the OC-48 OLIU. See
"Installing fiber connectors and
Connect the fibers labeled IN and OUT from the LGX to the OLIU (Port 1).
............................................................................................................................................................................................................................................................
6 - 4 4
S
F
T E P S
NOTICE
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
When reference is made to optical fiber loopback connections to IN and OUT
After a few moments, the ACTIVE LED should be lit on the OC-48
Table I-3, Installation acceptance
LBOs".