WDMX setup and testing: integration procedures
........................................................................................................................................................................
................................................................................................................................................
6
Click Select, then select REMAID and the port will appear on the right side of the screen,
click on the Port to highlight it then click Select.
................................................................................................................................................
7
Click Select for the Add/Drop port, expand the circuit pack (OMD5/8) and click on the
Port and the port will appear on the right side of the screen, click on the Port to highlight
it then click Select.
Note:
................................................................................................................................................
8
Click Next, then Finish and complete the cross-connection by clicking on Yes in the
confirmation window.
................................................................................................................................................
9
Connect fibers from Test port to selected channel on LNW785, while observing optical
power requirements and cleaning procedures. See
optical circuit pack laser safety specifications" (p. 1-11)
1665 DMX optical PTM laser safety specifications" (p. 1-12)
DMX optical power specifications.
Note:
inputs for individual channel-power control. It can perform automatic channel power
balancing of the add channels via the VOAs.
................................................................................................................................................
10
Repeat
................................................................................................................................................
11
Connect the Transmit fibers on the LNW785 at each end, following proper fiber cleaning
procedures.
................................................................................................................................................
12
Connect the Receive fibers on the LNW785 at each end, while observing optical power
requirements and cleaning procedures.
Result:
................................................................................................................................................
13
If adding a span in the other direction using the LNW785 repeat
otherwise continue.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
The port is determined by the test signal wavelength documented in
The LNW785 circuit pack has variable optical attenuators(VOAs) on the
Step 2
to
Step 9
at the remote Network Element.
Span is in-service
Turn-up and test the LNW785 8-channel OMD
Table 1-2, "Alcatel-Lucent 1665 DMX