Alarm messages

Ethernet interface Not expected input signal

...................................................................................................................................................................................................................................
Alarm identifier
Information
Alarm category
ASAP
Alarm severity
(default setting)
Reporting state
(default setting)
Local indications
Cause
Actions
...................................................................................................................................................................................................................................
365-312-803R7.2
Issue 4, May 2007
LANcNES
An incoming signal has been detected on an Ethernet interface although the
port is provisioned "Not Monitored".
Transmission
ethPS
Information
Not Reported
There are two possible reasons:
1. Either the port is intentionally not in use, and therefore is provisioned "Not
Monitored", but mistakenly an input signal is applied (due to erroneous
routing of intermediate cabling for example), or
2. although an input signal is applied, the port is mistakenly provisioned "Not
Monitored".
Change the port monitoring mode to "Monitored", or check the cabling (and
re-arrange if necessary).