OC-3/12/48 ring setup and testing: integration
procedures
........................................................................................................................................................................
Unterminated optical connectors may emit laser radiation. Do not view beam with
optical instruments.
Note:
invalid signal during installation, no alarms are reported since the receive port at the
opposite end of the span has not transitioned from AUTO to IS, even though the
measured receive power is within acceptable levels.
The failed transmit pluggable transmission module appears as an LOS to the receive
pluggable transmission module causing the port state to remain AUTO.
If the receive pluggable transmission module is receiving a signal within acceptable
levels but does not transition from AUTO to IS, replace the transmit pluggable
transmission module at the opposite end of the span.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
WARNING
Laser hazard
NOTICE
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
If the transmit pluggable tranmission module is failed and transmitting an
Fiber installation
8 - 3