8
OC-3/12/48 ring setup
and testing: integration
procedures
Overview
Purpose
This procedure is used to make fiber connections between Alcatel-Lucent 1665 Data
Multiplexer (Alcatel-Lucent 1665 DMX) nodes in a ring. It is not intended to replace
acceptance test procedures. If problems are encountered, see Alcatel-Lucent 1665 Data
Multiplexer (DMX) Alarm Messages and Trouble Clearing Guide, 365-372-302 for
detailed troubleshooting procedures.
If additional provisioning procedures are desired, see Alcatel-Lucent 1665 Data
Multiplexer (DMX) User Operations Guide, 365-372-301.
Contents
This chapter provides information on the following topics
Tools, test equipment and accessories
Fiber installation
Optical transmission test (OC-192, OC-48, OC-12)
Automatic protection switching test
Manual switching tests
Final operations
Tools, test equipment and accessories
The tools, test equipment and accessories necessary to perform the procedures in this
section are listed in
........................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
Tools, test equipment, and accessories (p.
8-1
8-2
8-9
8-10
8-12
8-14
III-2).
8 - 1