Installation tests
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
6
While observing the error-free transmission at the DSX, grasp the DS3 cable about two
inches from the BNC connector head and gently rotate (twist) the cable in a clockwise and
counter clockwise direction about 45 degrees (gently).
Result:
connector must be cut off and replaced.
If an error-free signal is not received:
Check the LBOs settings using the
DS3/EC1 and TMUX LBOs (p.
Verify that the pack is provisioned for the framing format being sent from the test set,
M13.
Verify that the port is provisioned for DS3. See
Check the DS3/EC1 cabling for proper connections.
........................................................................................................................................................................................................................
7
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

DS3 protection switching

DS3 function unit protection switching test (manual)
Use this procedure to test all of the Function unit Slots occupied with an LNW16
(DS3/EC1), LNW19/LNW19B (48DS3/EC1), LNW18 (TMUX) or LNW20 (48TMUX)
circuit pack, whether they are cabled to a DSX or terminating equipment.
Note:
arrangement.
It is not mandatory to perform this test on each sts cross-connection, however this
procedure should be performed on each Function unit Slot pair.
........................................................................................................................................................................................................................
1
Locate the Function Group equipped with the DS3/TMUX circuit pack.
........................................................................................................................................................................................................................
2
Unseat the active circuit pack. The active circuit pack has an ACTIVE LED lit.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
If any errors are detected while performing this "wiggle test," the BNC
S
F
T E P S
This test is performed when the DS3 circuit packs are in a 1x1 protection
View > Equipment
6-3).
Verify provisioning (p.
Table I-3, Installation acceptance
DS3 protection switching
command (see
Setting
6-18).
checklist.
6 - 2 3