Cable and fiber installation
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
4
Route the cables along the cable rack and into the terminating bay (DSX or other
terminating transmission equipment).
........................................................................................................................................................................................................................
5
Cut the cables to desired length and install the BNC connectors shipped with the cable
assemblies.
Note:
carefully to ensure a proper connection. Failure to do so may result in faulty DS3
signals as a result of improperly installed BNC connectors.
........................................................................................................................................................................................................................
6
Connect the cables to their respective positions on the terminating equipment.
Note:
the circuit pack not the backplane. There is no issue interchanging these cables on the
backplane. The Signals are common between both cables.
........................................................................................................................................................................................................................
7
Verify DS3 cabling using the LNW74 TESTPK or equivalent method.
........................................................................................................................................................................................................................
8
Check off the appropriate box in
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
When installing BNC connectors, follow the manufacturer's instruction
The 12-port cable and the 24-port cable use different signal grounds based on
S
F
T E P S
DS3/EC1 and TMUX 48-port cable installation
Table I-3, Installation acceptance
checklist.
3 - 1 7