OC-3/12/48 ring setup and testing: integration
procedures
........................................................................................................................................................................
Function units/growth slots, switching test
This test will initiate switching commands from the CIT and verify proper switching and
LED indications.
Note:
protected electrical TDM circuit packs.
................................................................................................................................................
1
Select Fault > Protection Switch...
................................................................................................................................................
2
Click on 1+1 Equip fn-x (x is a,b,c or d corresponding to the function group equipped).
................................................................................................................................................
3
Click Select.
................................................................................................................................................
4
Note which Function unit or Growth Slot circuit pack is the active circuit pack.
................................................................................................................................................
5
In the Switch Type: pull-down, select Manual (Normal).
................................................................................................................................................
6
Click Apply.
Result:
was standby is now active. Transmission should take a momentary hit as it is switched
to the other pack. This information should agree with the ACTIVE LEDs on the circuit
packs.
................................................................................................................................................
7
Repeat
pack, with the same results as the previous step.
................................................................................................................................................
8
Repeat this procedure for each Function unit pair.
................................................................................................................................................
9
Swap circuit packs from another function group to test any unequipped function slots.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
This procedure should be performed on each Function unit equipped with
The pack that was active should now be the standby pack and the pack that
Step 1
through
Step 6
to verify a switch back to the original Function unit circuit
Manual switching tests
8 - 1 3