Connector References - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Cable and fiber installation
............................................................................................................................................................................................................................................................
Notes:
1. One CIT Cable Assembly or Crossover LAN cable is required for PC interface with the
Alcatel-Lucent 1665 DMX high-capacity shelf (not included with equipment).
2. a. One DS1 Cable Assembly is required for each Function unit equipped for 28 DS1 service (
LNW7). Each DS1 Cable Assembly consists of two separate cables, both containing 28 pairs
of 24 gauge cable. One cable is for input and the other cable is for output.
b.Two DS1 Cable Assemblies are required for each Function unit equipped for 56 DS1 service
(LNW8, LNW801). Each DS1 Cable Assembly consists of two separate cables, both
containing 28 pairs of 24 gauge cable. One cable is for input and the other cable is for output.
3. a. One DS3 Cable Assembly is required for each Function unit equipped for 12 DS3 service
(LNW16/LNW18). Each orderable code provides two cables One cable consists of 12 inputs
and the other cable consists of 12 outputs. One DS3 Cable Assembly equipped with 24-coax
cables may be used if growth to 48 DS3 packs is planned.
b. Two DS3 Cable Assemblies are required for each Function unit equipped for 48 DS3
service (LNW19B/LNW20). Each DS3 Cable Assembly consists of two separate cable
groups, both containing 735A cables. One cable consists of 24 inputs and the other cable
consists of 24 outputs.
4. One cable is required for channels 1 through 12 and another for channels 13 through 24
(LNW66). LNW74 provides only ports 1 through 16.
5. When cabling the Alcatel-Lucent 1665 DMX high-capacity shelf for office alarm
applications, one Office Alarm Cable Assembly is required for the bottom Alcatel-Lucent
1665 DMX shelf in a bay frame. One Office Alarm Mult Cable Assembly is required for each
additional Alcatel-Lucent 1665 DMX shelf in the bay frame.
For example, if four Alcatel-Lucent 1665 DMX shelves are located in a single 7-foot bay
frame, one Office Alarm Cable Assembly and three Office Alarm Mult Cable Assemblies are
required.
6. One misc. discrete cable per shelf as required.
7. These cables are used for IAO LAN (OSI/TCP-IP)/Front LAN (OSI/TCP-IP) connection (J16
and Front LAN port). LAN 10BaseT cross over cable should be used if the shelf is directly
connected to a PC and LAN 10BaseT straight through cable should be used if shelf is
connected to a hub.
8. Two cables per shelf for Ref1 and Ref2.
9. RS232 modem cable (RJ45 to 25-pin).

Connector references

Description
Figure 3-1, Connector types and pinouts (p. 3-5)
connectors used to interface with the Alcatel-Lucent 1665 DMX.
............................................................................................................................................................................................................................................................
3 - 4
provides the pinouts of some of the
Alcatel-Lucent 1665 DMX R9.0
Connector references
365-372-304R9.0 Issue 2
July 2010