Operational tests
........................................................................................................................................................................
Safety instructions
Note:
Unterminated optical connectors may emit laser radiation. Do not view beam with
optical instruments.

Office alarm test

Description
This test verifies proper operation and wiring of the office alarms.
Audible and visual reporting of critical, major, minor alarms will be verified.
Prerequisite
The following is a list of items to verify before beginning tests in this section.
The Alcatel-Lucent 1665 DMX Main OLIUs should be optically looped from the
previous section. Verify that the Alcatel-Lucent 1665 DMX shelf is clear of all alarms
(only green LEDs are lighted) prior to and after completing this test.
The office alarm cable will be temporarily connected during this procedure.
"Office alarm connections" (p. 7-3)
It is a requirement that alarms on the Alcatel-Lucent 1665 DMX do not affect and are
not affected by other equipment via office alarm connections. During this test, the
alarm state of other equipment connected to the same office alarms as the Alcatel-
Lucent 1665 DMX should be examined after creating or clearing every alarm.
........................................................................................................................................................................
7 - 2
All precautions should be observed when handling fiber.
WARNING
Laser hazard
NOTICE
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.
NOTICE
The operational tests in this section are run only in an out-of-service mode of
operation. Office alarms will normally be connected only during the office
alarm test to prevent constant alarms throughout this section.
lists the office alarm connections.
Office alarm test
Table 7-1,
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010