Alcatel-Lucent 1665 Installation Manual page 217

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
The Function unit slot under test must contain a 28 DS1 (LNW7) or a 56DS1/E1 (LNW8
or LNW801) circuit pack in order to perform this test. The 56DS1/E1 circuit packs can
only be used with high capacity shelves. If the Alcatel-Lucent 1665 DMX shelf is not fully
populated, it may be necessary to move the circuit pack(s) from slot to slot in order to test
all DS1 cabling.
Steps
This command creates a cross-connect to map the first DS1 of a DS1 circuit pack in a
Function unit to the first VT1.5 within the first VT Group of STS1 of the Main OLIUs.
........................................................................................................................................................................................................................
1
Log on to the Alcatel-Lucent 1665 DMX shelf using the CIT software as described in 5,
"Use of WaveStar
........................................................................................................................................................................................................................
2
Select Configuration > Cross-Connections...
........................................................................................................................................................................................................................
3
Use the Cross-Connection Wizard to enter a new cross-connection at the VT1.5 rate,
UPSR Ring Add/Drop, between m1-1-1-1-1 and fn1-1-1-1 (fn will be a,b,c or d
depending on the slot where the DS1 CP is located).
........................................................................................................................................................................................................................
4
At this point it is necessary to have the Customer Network Control Center establish a
terminal loopback at the port under test at the DS1 terminating equipment.
........................................................................................................................................................................................................................
5
Run a test transmission test to verify the electrical cabling.
Select Fault > Test > Transmission...
........................................................................................................................................................................................................................
6
Select the CP, VT Group and Port 1-1 (DS1) associated with the cross-connection
entered above.
........................................................................................................................................................................................................................
7
Select the FACILITY direction.
Result:
followed by 0 es (errored seconds).
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
®
CIT software" (p.
The results should indicate that the test ran for a duration of 60 seconds
Local equipment and cross-connect tests
5-6).
6 - 7