Automatic protection switching test

Description
This section provides the procedures for verifying the Alcatel-Lucent 1665 DMX shelf
automatic and manual protection switching.
Note the following:
These tests do NOT simulate circuit pack failures.
A properly grounded wrist strap must always be worn while handling circuit packs.
Prior to performing each test, the shelf under test must be clear of all alarms (that is,
only green LEDs are lighted).
........................................................................................................................................................................
8 - 1 0
The Response Window indicates no transmission errors.
Step 1
through
Step 6
Step 1
through
Step 7
Step 1
and
Step 8
for each node in the ring.
S
F
T E P S
substituting CP main-2 in
for all Alcatel-Lucent 1665 DMX shelves at the test
Table I-3, Installation acceptance
Automatic protection switching test
Step
2.
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2