1000Base-F And 100Base-F Fiber Installation - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Cable and fiber installation
............................................................................................................................................................................................................................................................
Steps
........................................................................................................................................................................................................................
1
See the engineering job specification. Determine the function slot where the pack will be
inserted. The OC-3/OC-12/OC-48 pack can be inserted into any of the function slots
including the growth slots.
........................................................................................................................................................................................................................
2
Label the optical fiber cables, indicating bay, shelf, function group, pack, and direction (IN
or OUT).
........................................................................................................................................................................................................................
3
Route optical fiber cables from the interconnecting equipment into the OC-3/OC-12/OC-
48 optical ports
........................................................................................................................................................................................................................
4
Place the optical fiber cables in a protective tube or channel.
........................................................................................................................................................................................................................
5
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

1000Base-F and 100Base-F fiber installation

Description
This section describes how to route the optical fiber cables from the interconnecting
equipment (for example, an LGX
LNW63, LNW64, LNW74, LNW87, and LNW170 Ethernet circuit packs. Multi-mode
optical fiber is required for LNW74 (100 Base-F ports) and LNW170 (100Base-F ports).
Single-mode fiber is required for LNW170 (1000Base-F ports).
The optical fiber cables will be connected to the optical ports after the circuit packs are
installed.
Note:
placed in a protective tube or channel, such as PVC tubing, or PANDUIT cable
channel, when running the cable from the Alcatel-Lucent 1665 DMX high-capacity
shelf to the cable rack. The fibers should be placed in the cable rack in a protective
channel with nothing on top of them. Cable ties should NOT be used with the optical
fiber cables.
............................................................................................................................................................................................................................................................
3 - 6 4
S
F
T E P S
The optical fiber cable is fragile and must be protected. The fibers should be
1000Base-F and 100Base-F fiber installation
Table I-3, Installation acceptance
®
optical fiber distributing frame) to the optical ports on
checklist.
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010