Oc-3 (Low-Speed) Testing - Alcatel-Lucent 1665 Installation Manual

Data multiplexer
Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests
............................................................................................................................................................................................................................................................
Result:
LEDs should be lit on the SYSCTL circuit pack.
The alarm on the SFP module will flash.
........................................................................................................................................................................................................................
5
From the system view click Alarm List to verify that the circuit pack alarm is associated
with the optical port being tested.
........................................................................................................................................................................................................................
6
Select Configuration > Update System... > Update All.
Requirement: The flashing FAULT LED should extinguish on the OLIU. There
should be no alarm indications on the Alcatel-Lucent 1665 DMX shelf.
........................................................................................................................................................................................................................
7
From the system view click Alarm List to verify that the circuit pack alarm is cleared.
........................................................................................................................................................................................................................
8
Repeat this entire procedure for each LNW37, LNW45, LNW49, LNW55, LNW62 or
LNW402 SFP equipped in the Alcatel-Lucent 1665 DMX shelf.
........................................................................................................................................................................................................................
9
Replace all protective dust covers on the LNW37, LNW45, LNW49, LNW55, LNW62 or
LNW402 SFP OLIU connectors (OLIU and LGX), that were removed to perform this
procedure.
........................................................................................................................................................................................................................
10
Check off the appropriate box in
E
O
N D
........................................................................................................................................................

OC-3 (low-speed) testing

OC-3 testing procedure
Perform the following steps for all Alcatel-Lucent 1665 DMX shelf function unit or
growth slots containing OC-3 OLIU circuit packs.
............................................................................................................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
The FAULT LED should begin flashing on the OLIU and only the MN and NE
S
F
T E P S
Table I-3, Installation acceptance
OC-3 (low-speed) testing
checklist.
6 - 3 5