Optical transmission test (OC-192, OC-48, OC-12)

Overview
The following test verifies error-free transmission between nodes.
Transmission test procedure
................................................................................................................................................
1
At the test location, select Performance > View PM Reports > OCn Section...
................................................................................................................................................
2
Choose CP main-1, Port 1
................................................................................................................................................
3
Click Select.
................................................................................................................................................
4
Select Time Period: 15-Min, Monitored Date: Current Date and Monitor Level: 0 UP.
........................................................................................................................................................................
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010
The adjacent node appears in the neighbor list.