Physical installation and powering
I
............................................................................................................................................................................................................................................................
Quantity
1
1
2 or 3
2 or 3
2
............................................................................................................................................................................................................................................................
I- 4
Description
DS3 Error Rate Test Set
ITE-7113
SONET Optical Test Set
LC-Type Optical Fiber
Jumper ITE-7169
(108918269)
15-dB LC-Type LBO
ITE-7196 (108279480)
LC-Type Optical Fiber
Jumper (108918269)
Noyes OFS 300-200X
Optical Fiber Scope
ITE-7129
2.5 mm Universal
Adapter Cap ITE-7129
D1
1.25mm Universal
Adapter Cap ITE-7129
D2
Noyes VFS-1 ITE-7187
1
Video Fiber Scope
Comments
A DS3 error rate test set is required for testing of
DS3 cabling. A T-BERD 209 or equivalent is
recommended.
An OC-3, OC-12 or OC-48 test set as required for
testing of optical circuit packs. An Agilent
OmniBER 718 or equivalent is recommended.
Two optical fiber jumpers with LC type
connectors are required to optically loop the
Alcatel-Lucent 1665 DMX shelf for test purposes.
In addition, for shelves containing optical circuit
packs in any of the Function unit slots, a single
optical fiber jumper is required for testing of the
individual ports.
Two 15-dB LBOs are required when optically
looping the Alcatel-Lucent 1665 DMX shelf for
test purposes. In addition, for shelves containing
optical circuit packs in any of the Function unit
slots, a single 15-dB LBO is required for testing of
the individual ports
Two optical fiber jumpers with LC type
connectors are required to optically loop the
Alcatel-Lucent 1665 DMX shelf for test purposes.
Optical Fiber Scope
For use with the Noyes OFS 300-200X Optical
Fiber Scope
This equipment may not be necessary at all
locations. It is to be used when the ports need to
be verified for cleanliness. If care is exercised
when cleaning fibers, the video scope may not be
needed
Overview
Alcatel-Lucent 1665 DMX R9.0
365-372-304R9.0 Issue 2
July 2010